Constant Voltage Regulator
Model: CV12/24-20
12/24 V @ 20 Amps
Introduction
15 Amp Constant Voltage Regulator
Excellent Control Features:
Constant Voltage
Constant Current
Half Cell Voltage Regulation
Very High Efficiency
Low Cost 12 or 24 or 36 / 6 or 12 or 24 V conversion down in voltage
High Performance
Transient Protection on all connections
Solar Converters Inc. is pleased to introduce a new product for
users of renewable energy. We have developed a Cathodic Regulator which
keeps your valuble system running at its peak performance and free of
corrosion. This unit also doubles as a Constant Voltage Regulator for
systems operating 12 Volt loads off of 24 Volt battery systems or any other
down conversion at up to 20 amps of load current converted at over 96%
efficiency.
Designed for peak performance and stabilty, this Cathodic Regulator/
Constant Voltage Regulator is a low cost, highly reliable unit built to
high quality standards. This unit is based upon the proven design of the
Power Tracker(TM).
Features
- Ideal for solar powered battery backed cathodic protection systems
very high efficiency maximizes the performance of your solar
investment while minimizing cost
- Ideal Constant Voltage Regulator - Operates 12 V loads from 24
Volt battery systems
- User adjustable output voltage, current limit and half cell
voltage regulation
- Automatic flipover between the different operating modes
- Remote control (instant on/off) and metering options available for
sequenced operation
Electrical Specifications
Input Voltage
10 V to 40 V input voltage range
Output Voltage: User adjustable
2.0 to 32.0 Volts
Output Current User adjustable
0 .1 to 20 amps
Half Cell Voltage User adjustable
0.2 to 1.0 Volts
Ripple at load (mv rms)
20
Efficiency
>96%
Transient protection
All inputs and outputs protected and tested
Optional additional protection available
Transient response (10% - 90%)
20 ms to return to regulation
User Controls
Adjustment potentiometer to adjust output
voltage, current limit and half cell regulation
Mechanical Specifications
Open Frame style for mount in NEMA enclosures
Also available in a 4" X 4" X 1.5" NEMA 4 box
Dimensions: 4.88" X 4.88" X 1.5"
Weight: approx 2 lbs.
Temperature Range: -40 deg C to 75 deg C
It is recommended, as with all electronics, that the unit not be
placed in direct sunshine.
Terminations:
Power Eurostyle terminal block, Wire size: #10 AWG
Signal Eurostyle terminal block, Wire size: #18 AWG
Humidity 90% non-condensing ,designed and tested for operation in a
NEMA 12, 4, 4X enclosure = weatherproof
Application Comments
1) It is recommended that the unit be placed in a system that
has an LVD capability, unit shuts down under 10 V input
2) When not operating in half cell voltage regulation, short half
cell sense to itself
3) Addition of simple tramsformer and diode bridge, unit becomes
AC powered
Note: In the interest of continuous product improvement, specifications